Remote-processing CAMBASIC Manual de usuario Pagina 174

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 208
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 173
CONFIG C ommands - 1
CONFIG AIN
Statement
SYNTAX: CONFIG AIN channel, input, range
Where: channel is 0 to range of inputs for your card.
input specified single ended or differential if supported on your card
range is voltage input, if supported on your card
PURPOSE: Initialize analog inputs
REMARK S: Refer to your hardwar e manual for power– up defaults, input and range parameters, if any. The
RPC -2300 is not configured w hile the RPC-2350 is configur ed for 0-5V, single ended for all
channels.
RELATED: none
EXAMPLE: 10 CONFIG AIN 0,0,1
Configures channel 0 for differential mode, 0 to + 5V, on the RP C-2350
ERROR: < Data negative> all parameters
< Data out of range> if illegal parameters
Vista de pagina 173
1 2 ... 169 170 171 172 173 174 175 176 177 178 179 ... 207 208

Comentarios a estos manuales

Sin comentarios